# How much of the noise folder should you check for missed bats?

Last updated: 2026-11-22. Written by the BioSonic team.

There is no official percentage. The BCT guidelines say to always verify a proportion of analysed data, but they give no figure for noise files. A defensible method is a random sample from each detector and survey period: if you check 300 random noise files and find no bats, you can be about 95% confident that fewer than 1% hold a bat. In BioSonic you can show the files the AI marked as noise, open and listen to them, and correct the species.

We make BioSonic. The method on this page works with any bat analysis software.

## How many noise files to check

If a random sample contains no bats, the rule of three gives the highest miss rate that is still plausible at 95% confidence: 3 divided by the number of files you checked.

| Random noise files checked, no bats found | Miss rate is likely below | In a noise folder of 10,000 files |
|---|---|---|
| 60 | 5% | Up to about 500 files could still hold bats |
| 100 | 3% | Up to about 300 files |
| 300 | 1% | Up to about 100 files |
| 600 | 0.5% | Up to about 50 files |

The table is statistics, not BCT guidance. It holds only if the sample is random and you can recognise the bats you are looking for. A very rare species can still be missed.

## A method you can write into a report

1. Split the noise files by detector and survey period, because a windy week or a faulty microphone behaves differently.
2. Draw a random sample from each part. The first files in a folder are not a random sample.
3. Check more where a quiet species is likely, such as barbastelle, long-eared bats and some Myotis.
4. If you find bats, record the species and how many, then check that detector and period in more depth.
5. Report how many noise files there were, how many you checked and how many held bats.

## Wording for the method section

> Files classified as noise were sampled at random for each detector and survey period. Of [total] noise files, [number] were checked by [name, role] and [number] contained bat calls. [Detectors or periods] were checked in more depth as a result.

## Checking noise in BioSonic

- Noise files are hidden in the file list at first. Press the Noise button to show them.
- Open any of them to see the spectrogram and listen, and set the species if it is a bat.
- Review options let a team check a random share of files or set its own rate per species, with noise as its own row.

## Common question

### Does BCT say how much of the noise folder to check?

No. The 4th edition says a proportion of data should always be verified for quality assurance, but we found no figure for noise files in it. Choose a sample, give the reason and report the result.

## Sources

- [Bat Surveys for Professional Ecologists, 4th edition](https://www.bats.org.uk/resources/guidance-for-professionals/bat-surveys-for-professional-ecologists-good-practice-guidelines-4th-edition) (Collins, ed., Bat Conservation Trust, 2023, amended March 2024), section 10.2.
- [Kaleidoscope Pro User Guide](https://media.nhbs.com/manuals/Kaleidoscope-User-Guide.pdf) (Wildlife Acoustics, updated 8 August 2023, copy hosted by NHBS), on how noise files are defined.

Related: [Why barbastelle calls end up as noise](https://biosonic.io/barbastelle-calls-noise-folder) · [Cut the time spent checking calls](https://biosonic.io/cut-bat-call-checking-time) · [What BCT says about auto ID](https://biosonic.io/bct-guidance-auto-id)

## Test it on a survey you know

Upload recordings you have already identified and compare the results and the time it took.